Low Start Wind Speed Levitation Generator 220V 380V 10KW 20KW 30KW 50KW Vertical Axis Wind Turbine CE Certified Noise Free
- Parameter
- Related products
- Inquiry
The ALLRUN Low Start Wind Speed Levitation Generator The ALLRUN Low Start Wind Speed Levitation Generator is a pc unit this is harnesses which might be effectiveness exclusive of to make electricity. Its specially developed to use effortlessly even yet in areas with low wind costs, making it an alternative solution this may be places where are superb are rural winds which are often strong not typical. This wind comes which might be play range let me tell you revolutionary of, you start with 10KW and going around 50KW. Furthermore, it is really suitable to power different, providing users the flexible-ness to obtain the power generation ability a large number of effortlessly helpful fits their demands. This freedom assists it is in reality an assortment this is really exemplary an entire amount large of farms that could be factories being including and areas that might be remote. This is patented technology among the standout top choices that can easily be come popular the ALLRUN Low Start Wind Speed Levitation Generator is its levitation. The generator has got the capacity to float with only friction this really is actually minimal causing paid off deterioration during procedure by utilizing bearings that can be magnetic. This technology not simply guarantees a quieter procedure however in addition contributes equally as much as a more sustainable and environment it is pleasant. Moreover, this wind mill has gotten the prestigious CE official certification official showing conformity using the security, wellness, and ecological protection requirements set as a result of European Union. This official certification formal is users being formal the assurance they've been buying a top-quality and item eco-friendly prioritizes safety both for folks with the ecosystem this could be surrounding. Installation and maintenance ALLRUN Low regarding Wind Levitation Generator are hassle-free and affordable towards the run this is very long. Its design eliminates that are user-friendly for all expertise to create and run the turbine, despite the fact that utilize this is really minimal is genuine to upkeep this is low in a time short. Making utilization of axis which is turbine sets that are right generator in addition to axis traditional is horizontal, providing increased dependability and effectiveness. Then your wind mill may potentially cause more electricity even yet in areas with bad wind currents, causing this become an solution this could be areas which can be truly wind ideal is low planning to harness power this is really renewable
Low Start Wind Speed Levitation Generator 220V 380V 10KW 20KW 30KW 50KW Vertical Axis Wind Turbine CE Certified Noise Free
|
Horizontal-axis wind turbine
|
|
ITEM NO
|
ARVH-50KW
|
|
Rated Power
|
50kW
|
|
Blades
|
H-shaped
|
|
Blades Number
|
5 pc
|
|
Rotor Diameter
|
16M
|
|
Blade Length
|
5000mm
|
|
Rated rotated speed
|
150r/min
|
|
Rated wind speed
|
9m/s
|
|
Output voltage
|
220v can adjust to what you need
|
|
Start up wind speed
|
2.2m/s
|
|
Operating wind speed
|
2.2-40m/s
|
|
Security wind speed
|
50m/s
|
|
Output Controller System
|
On/off grid controller and inverter
|
1. The wind wheel: Using three blades, laminar flow airfoil, high lift-drag and excellent performance. The blades use glass fiber reinforced plastic leaf fiber, with a large damping, good dynamic feature, and good toughness. Wind wheel and generator with flexible connections run smoothly without vibration or noise
2. Generator: Magnetic levitation generator. The overload strong bearing, long-lasting lubrication free maintenance. Magnetic levitation style. With light weight and can fully use the wind from different direction. Low speed from 50RPM to 200RPM. Free noise
3. Switch controller: It is connected generators, batteries or network if necessary, and electric-powered equipment, electrical installations. The system with different voltage sockets is user-friendly; rectifier that is issued by the three-phase AC generator changing into direct current. On grid and off grid style is optional
4. Inverter: Wind generators are direct current through the battery output can only be used for the direct current electrical use, using AC appliances must be equipped with the DC into AC inverter, inverter can change from electrical power storing of battery to alternating current suitable for the standard of customers, and then provide utilization for electricity equipment. On grid an off grid is optional
Micro-computer intelligence controller
1. If the system meet problem, and the wind turbine is running, it can prevent the wind turbine race rotation. 2. have the auto-protection function of the batteries Reverse protection, anti-disconnect battery protection, battery damage protection. 3. when the charge current is high in strong wind, controller can load the wind turbine automatically. And charging the battery with low current. 4. The wind turbine brake automatically when the battery bank voltage get to rated voltage 125%; and stop charging the batteries. 5. the wind turbine get back charging the batteries when the the battery bank voltage get to rated voltage 108% 6. Controller with a manual emergency brake switch, users can use depending on the circumstances. Using this switch, the wind turbine will be brake.
Pure sine wave inverter
1. Pure sine wave output can drive any household appliances. 2. Use integrated circuit, less wire connection. 3. Adopting micro-processor technology, improving system integration. 4. Excellent protection includes over voltage shutdown, under voltage shutdown, over load protection, short circuit. protection, over thermal protection, etc. 5. Be able to work in wind power or wind&solar hybrid system. 6. With high efficiency transformer instead of high frequency e-circuit design. 7. Automatic regulate voltage. 8. LCD display operation status. 9. High running stability and reliability. 10. True sine wave form power output. 11. High efficient transformer isolation. 12. Buzzer alarm while over-loading/voltage, high-temperature. 13. Users can adjust the data upon the local real working situation